Logon and LogOff
Message is “Logon” (35=A)
bothbothMDOBTRDCRQ
| Tag | Name | Required | Notes |
|---|---|---|---|
| 98 | EncryptMethod | Required | 0=None |
| 108 | HeartBtInt | Required | Heartbeat interval in seconds; default 30 |
| 141 | ResetSeqNumFlag | Optional | Y=Reset sequence numbersY to reset sequence numbers; used on MD and OB sessions |
To start a FIX session with OpenYield, send a Logon (35=A) message. OpenYield will confirm with its own Logon (35=A).
Subscribers send:
OpenYield responds with:
Message is “Logout” (35=5)
bothbothMDOBTRDCRQ
| Tag | Name | Required | Notes |
|---|---|---|---|
| 58 | Text | Optional | Optional reason for logout |
To end a session, send a Logout (35=5) message.
Market Data and Order Book sessions always reconnect with ResetSeqNumFlag (141=Y):